Fuel gas cylinders shall be placed with valve end up whenever they are in use. Arc welding and cutting operations shall be separated from other operations by shields, screens, or curtains to protect employees in the vicinity from the direct rays and sparks of the arc. 1926.702 - Requirements for equipment and tools. %PDF-1.7 % The entry permit that documents compliance with this section and authorizes entry to a permit space must identify: 1926.1206 (a) The permit space to be entered; 1926.1206 (b) The purpose of the entry; 1926.1206 (c) The date and the authorized duration of the entry permit; 1926.1206 (d) The California Code of Regulations (CCR), title 8, section 341 and section 341.1 require employers to obtain Project Permits and Annual Permits from Cal/OSHA before conducting certain construction activities. Fuel gas and oxygen hoses shall be easily distinguishable from each other by color or sense of touch. Articles from Wex Table of Popular Names Parallel Table of Authorities When welders are exposed to their own arc or to each other's arc, they shall wear filter lenses complying with the requirements of paragraph (h) of this section. Where relocation is impractical, combustibles shall be protected with flame proof covers, shielded with metal, guards, curtains, or wet down material to help prevent ignition of . 1926.449 - Definitions applicable to this subpart. 1926.903 - Underground transportation of explosives. 1926.61 - Retention of DOT markings, placards and labels. Note to paragraph (i). 1926 Subpart R App H - Double Connections: Illustration of a Clipped End Connection and a Staggered Connection: Non-Mandatory Guidelines for Complying with 1926.756(c)(1). 0000052551 00000 n 1926.954 - Personal protective equipment. 0000065715 00000 n 1926.1414 - Wire ropeselection and installation criteria. 2 A Project Permit authorizes an employer serving as a Project Administrator to conduct permit-required activity at specific location (s) Any employee exposed to the same atmosphere as the welder or burner shall be protected by the same type of respiratory and other protective equipment as that worn by the welder or burner. 1926.62 App A - Substance Data Sheet for Occupational Exposure to Lead, 1926.62 App B - Employee Standard Summary, 1926.62 App C - Medical Surveillance Guidelines. Before a regulator is removed from a cylinder valve, the cylinder valve shall always be closed and the gas released from the regulator. Those measures can include, but are not limited to, the lockout or tagging of equipment and procedures for purging, inerting, ventilating, and flushing permit spaces. }m?"Qwk&Ubm5"W`K`!xC_[2Vk"e,X,bYGv`[=. Each employer who identifies, or receives notice of, a permit space and has not authorized employees it directs to work in that space must take effective measures to prevent those employees from entering that permit space, in addition to complying with all other applicable requirements of this standard. They shall not be located within enclosed spaces. 1910.252 (a) (1) (ii) Guards. Fill in the necessary boxes that are colored in yellow. Hot work includes cutting, welding, brazing, soldering, and any process involving the application of a naked flame. Empty containers shall be removed from the hot work area. 1926.2 - Variances from safety and health standards. 0000052163 00000 n 1926.55 - Gases, vapors, fumes, dusts, and mists. 0000009131 00000 n Highly flammable coatings shall be stripped from the area to be heated. 0000035922 00000 n When a special wrench is required, it shall be left in position on the stem of the valve while the cylinder is in use so that the fuel gas flow can be shut off quickly in case of an emergency. 1926.50 App A - Medical services and first aid. Areas can be protected with the use of welding pads, blankets, or curtains, clearing combustibles from a 35-ft (11-m) radius space around the hot work, or moving the hot work to an area free of combustibles. 0000004560 00000 n 0000010051 00000 n 1926.97 - Electrical protective equipment. PDF Hot Work Safety - Nfpa Safety Brief - Hot Work Permits | Environmental Health and Safety 1926.1411 - Power line safetywhile traveling. hb`````P}AX8v00 x(dAn^>OM 5a&FAA@2 (h `@y mA`93N03d7(`pa8 TPj~!A2uWqV )2,[X{0=# The Hot Work Permit is key to managing hot and preventing fires. 1926 Subpart V App A - Appendix A to Subpart V of Part 1926 [Reserved], 1926 Subpart V App B - Appendix B to Subpart V of Part 1926-Working on Exposed Energized Parts, 1926 Subpart V App C - Appendix C to Subpart V of Part 1926-Protection From Hazardous Differences in Electric Potential, 1926 Subpart V App D - Appendix D to Subpart V of Part 1926 - Methods of Inspecting and Testing Wood Poles, 1926 Subpart V App E - Appendix E to Subpart V of Part 1926 - Protection From Flames and Electric Arcs, 1926 Subpart V App F - Appendix F to Subpart V of Part 1926 - Work-Positioning Equipment Inspection Guidelines, 1926 Subpart V App G - Appendix G to Subpart V of Part 1926 - Reference Documents, 1926 Subpart W - Rollover Protective Structures; Overhead Protection. When electrode holders are left unattended, electrodes shall be removed and holders placed to prevent employee injury. ___ Smoke detectors in the area of hot work have been covered to prevent false alarms. When cylinders are transported by powered vehicles, they shall be secured in a vertical position. Defective hose, or hose in doubtful condition, shall not be used. 0000009657 00000 n 1926.350 Gas Welding and Cutting 1926.350 (a) Transporting, Moving, and Storing Compressed Gas Cylinders 1926.350 (a) (1) Valve protection caps shall be in place and secured. 1926.1208 - Duties of authorized entrants. No one shall use a cylinder's contents for purposes other than those intended by the supplier. 1926 Subpart M App A - Determining Roof Widths - Non-mandatory Guidelines for Complying with 1926.501(b)(10), 1926 Subpart M App B - Guardrail Systems - Non-Mandatory Guidelines for Complying with 1926.502(b), 1926 Subpart M App C - Personal Fall Arrest Systems - Non-Mandatory Guidelines for Complying with 1926.502(d), 1926 Subpart M App D - Positioning Device Systems - Non-Mandatory Guidelines for Complying with 1926.502(e), 1926 Subpart M App E - Sample Fall Protection Plan - Non-Mandatory Guidelines for Complying with 1926.502(k), 1926 Subpart N - Helicopters, Hoists, Elevators, and Conveyors. Other OSHA regulations, however, do not (although it is often advisable to retain certain documents even if retention is. a. OSHA amended 29 CFR Part 1960 to implement its "Multi-Employer Worksite Policy" in the federal sector, as stated in 60 Federal Register (FR) 35040. 1926.155 - Definitions applicable to this subpart. 1929 wheat penny. When entrance covers are removed, the opening must be immediately guarded by a railing, temporary cover, or other temporary barrier that will prevent an accidental fall through the opening and that will protect each employee working in the space from foreign objects entering the space. 0000006757 00000 n 1926.95 - Criteria for personal protective equipment. 1926.956 - Hand and portable power equipment. 1926.1410 - Power line safety (all voltages)equipment operations closer than the Table A zone. 0000007213 00000 n Lou, Paris 11eme, recherche des personnes motives et comptentes qui partagent notre enthousiasme pour la gastronomie, le vin et l'hospitalit pour devenir Chef de Parties dans notre quipe . Cylinders shall be moved by tilting and rolling them on their bottom edges. PDF Hot work procedures - Ohio Except as specified in paragraphs (f)(3)(ii) and (f)(3)(iii) of this section, when hot work is performed in a confined space the employer shall ensure that: General mechanical or local exhaust ventilations shall be provided; or. Table G-1 - Filter Lenses for Protection Against Radiant Energy. Hose shall be inspected before use. Nomenclature changes to part 1926 appear at 84 FR 21597, May 14, 2019. Fuel gas and oxygen manifolds shall bear the name of the substance they contain in letters at least 1-inch high which shall be either painted on the manifold or on a sign permanently attached to it. They shall not be hoisted or transported by means of magnets or choker slings. U |`" endstream endobj 68 0 obj <>>> endobj 69 0 obj <> endobj 70 0 obj >/PageUIDList<0 247>>/PageWidthList<0 612.0>>>>>>/Resources<>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageC]/Properties<>/XObject<>>>/Rotate 0/Tabs/W/Thumb 62 0 R/TrimBox[0.0 0.0 612.0 792.0]/Type/Page>> endobj 71 0 obj <> endobj 72 0 obj <> endobj 73 0 obj <> endobj 74 0 obj <> endobj 75 0 obj <> endobj 76 0 obj <> endobj 77 0 obj <>stream Surfaces covered with preservative coatings shall be stripped for at least 4 inches (10.16 cm) from the area of heat application or employees shall be protected by supplied air respirators in accordance with the requirements of 1910.134 of this chapter. Nothing shall be placed on top of a cylinder or associated parts when the cylinder is in use. 1926.1404 - Assembly/Disassemblygeneral requirements (applies to all assembly and disassembly operations). Sharing procedures. Create this form in 5 minutes! OSHA Laws & Regulations 1926 Regulations (Standards - 29 CFR) By Standard Number Standard Number > 1926 1926 - Table of Contents 1926 Subpart A - General 1926.1 - Purpose and scope. Hot Work Safety - Safety Toolbox 1926.1406 - Assembly/Disassemblyemployer procedures--general requirements. 0000052058 00000 n A single hose having more than one gas passage shall not be used. 0000033273 00000 n Hose couplings shall not unlock or disconnect without rotary motion. 1926.151 Fire prevention. 1926.962 - Grounding for the protection of employees. When hot work must be performed in a location that is not free of fire hazards, all necessary precautions shall be taken to confine heat, sparks, and slag so that they cannot contact flammable or combustible material. 0000002304 00000 n 1926.450 - Scope, application and definitions applicable to this subpart. Regulators and gauges. Exposed metal parts shall be insulated. trailer <<1B13CD194470406EBFF083678E0EF562>]/Prev 264003>> startxref 0 %%EOF 132 0 obj <>stream Workers, supervisors, fire wardens, and contractors should be trained specific to their roles. 1926.1203 - General requirements. | Occupational Safety and Health Before entry operations begin, the host employer must provide the following information, if it has it, to the controlling contractor: The hazards or potential hazards in each space or the reason it is a permit space; and. Warm, not boiling, water shall be used to thaw cylinders loose. 0000025889 00000 n 0000003523 00000 n |_W+B s&M07Any'hz)(QM/Q^F>cE>]co7 F~o7 F~o7W*UI J_YZhx3cJkCp{]~pq B* endstream endobj 81 0 obj <>stream Hot Work Definition and Requirements | US EPA Hot Work Permit Template: Free PDF Download | SafetyCulture When arc welding is performed in wet or high-humidity conditions, employees shall use additional protection, such as rubber pads or boots, against electric shock. Pressure regulators. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Welding Hazards burns & fire impact penetration 1926.1107 - 3,3'-Dichlorobenzidine (and its salts). Oxygen shall not be used for ventilation, cooling or cleaning clothing or work areas. 1926.914 - Definitions applicable to this subpart. Open end fuel gas and oxygen hoses shall be immediately removed from enclosed spaces when they are disconnected from the torch or other gas-consuming device. 1926.66 - Criteria for design and construction of spray booths. 0000065676 00000 n When openings or cracks in flooring cannot be closed, precautions shall be taken to ensure that no employees or flammable or combustible materials on the floor below are exposed to sparks dropping through the floor. When welding, cutting, or heating is performed on walls, floors, and ceilings, since direct penetration of sparks or heat transfer may introduce a fire hazard to an adjacent area, the same precautions shall be taken on the opposite side as are taken on the side on which the welding is being performed. Hot electrode holders shall not be dipped in water. Hose connections shall be kept free of grease and oil. 29 CFR Subpart F - Fire Protection and Prevention Building: Location: Description of Hot Work: Name of Hot Work Operator: hot work have been covered with a wet rag. 1926 Subpart S App A - Decompression Tables. 1926.1437 - Floating cranes/derricks and land cranes/derricks on barges. Manifold hose connections, including both ends of the supply hose that lead to the manifold, shall be such that the hose cannot be interchanged between fuel gas and oxygen manifolds and supply header connections. Know OSHA's Document Creation, Retention Requirements - SHRM An uncoiled fire hose with fog nozzle, under pressure, shall be immediately available in the hot work area. 1926.1002 - Protective frames (roll-over protective structures, known as ROPS) for wheel-type agricultural and industrial tractors used in construction. 0000006244 00000 n ___ A Fire Watch has been posted, if it is required, during hot work operations and for 30 minutes after work has been completed. 1926.12 - Reorganization Plan No. Get access to thousands of forms. Adapters shall not be used to permit the interchange of hose. 1926.432 - Environmental deterioration of equipment. The valve of a fuel gas cylinder shall not be cracked where the gas would reach welding work, sparks, flame, or other possible sources of ignition. 1926 Subpart P App A - Soil Classification, 1926 Subpart P App B - Sloping and Benching, 1926 Subpart P App C - Timber Shoring for Trenches, 1926 Subpart P App D - Aluminum Hydraulic Shoring for Trenches, 1926 Subpart P App E - Alternatives to Timber Shoring, 1926 Subpart P App F - Selection of Protective Systems, 1926 Subpart Q - Concrete and Masonry Construction. Electrodes shall not be struck against a cylinder to strike an arc. Shut down all operation if you discover a fire hazard without a fire watch. 1926.964 - Overhead lines and live-line barehand work. If, when the valve on a fuel gas cylinder is opened, there is found to be a leak around the valve stem, the valve shall be closed and the gland nut tightened. Employees exposed to radiation shall have their skin covered completely to prevent ultraviolet burns and damage. The following requirements apply to entry into permit spaces that meet the conditions set forth in paragraph (e)(1) of this section: Any conditions making it unsafe to remove an entrance cover must be eliminated before the cover is removed. Oxygen cylinders and fittings shall be kept away from oil or grease. 1926.1427 - Operator training, certification, and evaluation. Training. 1926.1429 - Qualifications of maintenance & repair employees. The certification must be made available to each employee entering the space or to that employee's authorized representative; and. Arc welding and cutting cables shall be insulated, flexible and capable of handling the maximum current required by the operations, taking into account the duty cycles. Such personnel shall be instructed as to the specific anticipated fire hazards and how the firefighting equipment provided is to be used. Standard for Fire Prevention During Welding, Cutting, and Other Hot Work This standard presents provisions to prevent injury, loss of life, and loss of property from fire or explosion as a result of hot work projects such as welding, heat treating, grinding, and similar applications producing or using sparks, flames, or heat. They shall not be placed in a location where they would be subject to open flame, hot metal, or other sources of artificial heat. . Metals coated with mercury-bearing materials. Insert the date. Local exhaust ventilation shall consist of movable hoods positioned close to the work and shall be of such capacity and arrangement as to keep breathing zone concentrations below hazardous levels. How to Create OSHA Work Permits | Lion Technology 1926 Subpart D - Occupational Health and Environmental Controls. Before heat is applied to a drum, container, or hollow structure, a vent or opening shall be provided for the release of any built-up pressure during the application of heat. Arc welding and cutting machine frames shall be grounded, either through a third wire in the cable containing the circuit conductor or through a separate wire at the source of the current. HOT WORK SAFETY GUIDE . 1926.104 - Safety belts, lifelines, and lanyards. 0000065789 00000 n 0000075649 00000 n Near any area in which exposed readily ignitable materials such as bulk sulphur, baled paper or cotton are stored. hot work training. 1926.107 - Definitions applicable to this subpart. 1926 Subpart Y App A - Examples of Conditions Which May Restrict or Limit Exposure to Hyperbaric Conditions, 1926 Subpart Y App B - Guidelines for Scientific Diving, 1926 Subpart Z - Toxic and Hazardous Substances, 1926.1101 App A - OSHA Reference Method - Mandatory, 1926.1101 App B - Sampling and Analysis - Non-mandatory, 1926.1101 App C - Qualitative and quantitative fit testing procedures - Mandatory, 1926.1101 App D - Medical Questionnaires; Mandatory, 1926.1101 App E - Classification of Chest X-Rays - Mandatory, 1926.1101 App F - Work practices and engineering controls for Class I Asbestos Operations - non-mandatory, 1926.1101 App H - Substance Technical Information for Asbestos - Non-Mandatory, 1926.1101 App I - Medical Surveillance Guidelines for Asbestos, Non-Mandatory, 1926.1101 App J - Smoking cessation program information for asbestos, non-mandatory, 1926.1101 App K - Polarized Light Microscopy of Asbestos - Non-Mandatory. In confined or enclosed spaces, hot work involving the following metals shall only be performed with general mechanical or local exhaust ventilation that ensures that employees are not exposed to hazardous levels of fumes: Chromium-bearing metals or metals coated with chromium-bearing materials. No damaged or defective cylinder shall be used. 1926.441 - Batteries and battery charging. Welding, Cutting, and Other Hot Work. 1926.20 - General safety and health provisions. sb`aY 1926.703 - Requirements for cast-in-place Concrete. 3. 1926 Subpart U - Blasting and the Use of Explosives. 1926.1103 - 13 Carcinogens (4-Nitrobiphenyl, etc.). 1926.856 - Removal of walls, floors, and material with equipment. Current Edition: 2019 1926.3 - Inspections - right of entry. Oil shall not be used to lubricate caps; Shall be hoisted only while secured, as on a cradle or pallet, and shall not be hoisted by magnet, choker sling or cylinder caps; Shall be moved only by tilting or rolling on their bottom edges; Shall have valves closed when cylinders are empty, being moved or stored; Shall be secured upright except when hoisted or carried; Shall not be freed when frozen by prying the valves or caps with bars or by hitting the valve with a tool; Shall not be exposed to sparks, hot slag, or flame; Shall not be permitted to become part of electrical circuits or have electrodes struck against them to strike arcs; Shall not be used as rollers or supports; Shall not have contents used for purposes not authorized by the supplier; Shall not be used if damaged or defective; Shall not have gases mixed within, except by gas suppliers; Shall be stored so that oxygen cylinders are separated from fuel gas cylinders and combustible materials by either a minimum distance of 20 feet (6.1 m) or a barrier having a fire-resistance rating of 30 minutes; and. PDF Hot Work Permit For Compliance With - California State University San If a plug or safety device leaks, the cylinder shall be tagged, removed from service, and moved to a location where the leak will not be hazardous. Hot Work Permit Osha Standard: Fill & Download for Free - CocoDoc 0000018041 00000 n Grounding circuits shall have resistance low enough to permit sufficient current to flow to cause the fuse or circuit breaker to interrupt the current.